solar and sustainable design solutions
home
federal

BYRON G. ROGERS U.S. COURTHOUSE, Denver, Colorado

The Byron G. Rogers U.S. Courthouse, a 265,000 sf $45.8 million renovation project in Denver, is the first General Services Administration (GSA) owned LEED for Existing Building certified building and the first GSA LEED Gold rated building. ambient energy facilitated a sustainable design charrette and meetings, managed LEED construction administration, reviewed drawings & specifications for LEED compliance, performed DOE2 energy modeling, calibrated energy model to utility bills, performed initial ENERGY STAR benchmarking, and is performing ongoing quarterly reporting for three years. The Courthouse is saving:

  • 32% on interior water usage; 50% on exterior water usage
  • 30% on energy costs
  • 100% of electric energy usage is Wind Power
  • 50% of open space is vegetated with native of adapted vegetation
  • 50% of all building materials have recycled content
  • 50% of all wood based materials are from sustainability harvested forests
  • 50% of occupants utilize the public transportation program provided by the GSA
  • 3% walk and 5% carpool to the building site
Byron Rogers Courthouse

ALFRED ARRAJ U.S. COURTHOUSE, Denver, Colorado

Sustainable design consulting for a 320,000 sf office and courtroom building pursuing LEED for Existing Buildings Silver rating. Tasks include LEED facilitation and Online submittal, sustainable design charrette, ENERGY STAR benchmarking, and set-up of reporting and policies for GSA contractors.

US AIR FORCE ACADEMY, CADET GYM, Colorado Springs, CO

Sustainable design charrette facilitation for Cadet Gym. Researched federal requirements US Air Force requirements, presentation development, LEED-CI and LEED-EB presentation development.

us afa, cadet gym
image: RNL

U.S. DEPARTMENT OF MILITARY AND VETERANS AFFAIRS, GRAND JUNCTION FACILITY MAINTENANCE SHOP No.3, Grand Junction, CO

LEED consulting and DOE2 energy modeling. Energy and life cycle cost effectiveness of the following measures were determined: higher levels of wall and roof insulation, glazing tuned for orientation, higher efficiency boiler, alternative heat wheel heat recovery, higher efficiency cooling system in office, indirect evaporative cooling, ground source heat pumps, and photovoltaics.

us domva, maintenance shop

U.S. AIR FORCE ACADEMY, VANDENBERG HALL, Colorado Springs, CO

DOE2 energy modeling and life cycle analysis on several window replacement options for 800,000 square foot dormitory.

usaf vandenburg hall
image: Visual Architectural Rendering and klipp

U.S. SHRIEVER AIR FORCE BASE, Colorado Springs, CO

Comparison of solar preheating of boiler feedwater options using parabolic trough, glazed, and unglazed solar thermal collectors including an hourly simulation and life cycle cost analysis. Results found that the parabolic trough evacuated tube collectors had the most favorable economics.

denver justice center, detention center
top